Digital display visible spectrophotometer 721 Professional vis spectrophotometer

Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Digital display visible spectrophotometer 721 Professional vis spectrophotometer

Digital display visible spectrophotometer 721 Professional vis spectrophotometer
Welcome to our store, we have high-quality pre-sales and after-sales service. I wish you all the best. Digital display visible spectrophotometer 721 Professional vis spectrophotometer. Excellent metering accuracy is higher than that of the same instrument. It is widely used in medical testing, food, petrochemical industry, environmental protection and monitoring. Digital display measurement value. Automatic light door, automatic zero adjustment and 100 instrument calibration. Use original imported tungsten lamp to ensure the service life of the instrument. Large sample room, can hold up to 10cm cuvette. Optical system: achromatic Czerny-Turner (1200L / mm grating). Photometric accuracy: 0.5% T. Photometric repeatability: 0.2% T. Working mode: T, A, C. Wavelength drive mode: manual wavelength. Energy (light source): tungsten lamp. 1 x visible spectrophotometer. 1 x power cord. 1 x glass cuvette. The instrument should be placed in a dry room. When used, it should be placed on a firm and stable workbench. The indoor lighting should not be too strong. In the hot weather, you can not use the fan to blow directly to the instrument to prevent the bulb filament from becoming bright and unstable. Before using the instrument, the user should first understand the structure and working principle of the instrument, as well as the functions of each control knob. Before the power is turned on, the safety performance of the instrument should be checked. The power supply wiring should be firm and the power supply should be good. The starting position of each adjustment knob should be correct, and then press the power switch. When the instrument has not been powered on, the meter pointer must be on the “O” engraving line. If this is not the case, you can adjust it with the calibration screw on the meter. Temperature and humidity are important factors affecting the performance of the instrument. They can cause corrosion of mechanical parts, reduce the smoothness of the metal mirror surface, cause errors or performance degradation of the mechanical parts of the instrument; cause optical components such as gratings, mirrors, focusing mirrors, etc. The aluminum film is rusted, resulting in insufficient light energy. Stray light, noise, etc. Even the instrument stops working, thus affecting the life of the instrument. It should be regularly corrected during maintenance. It should have an instrument room with four seasons and constant humidity, and be equipped with constant temperature equipment, especially ground. Laboratory in the southern region. 2, dust and corrosive gases in the environment can also affect the flexibility of the mechanical system, reduce the reliability of various limit switches, buttons, photoelectric couplers, and also cause one of the reasons why the aluminum film corrosion of the components must be learned. Clean, protect the environment and the indoor sanitary conditions of the instrument, dustproof. After the instrument has been used for a certain period of time, a certain amount of dust will accumulate inside. It is best to start the dust removal work by the maintenance engineer or the engineer under the guidance of the engineer, and re-tighten the radiator of each heating element. The sealed window of the box is cleaned. If necessary, calibrate the optical path, clean the mechanical parts and necessary lubrication, and finally, restore the original condition, and then perform some necessary tests, adjustments and records. Feedback is very important to us. It is impossible to address issues if we do not know about them! Faction is our ultimate goal. We work hard to earn your trust and future business. A If you receive a defective item, you may return it or ask for a discount. Due to time zones, our reply to your questions may not be immediately. If it’s non-workdays, please kindly be patient and wait till Monday.
Digital display visible spectrophotometer 721 Professional vis spectrophotometer